Adaptive Hysteresis Band Current ControlImproving Power Quality Using a Fuzzy Inference System-Based Variable Forgetting Factor Recursive Least Error Square Control Scheme of DSTATCOM [Volume 3, Issue 2, 2024, Pages 185-199]
Additional harmonicsImproving the Performance of a VSG in the Distorted Grid Using Third-Order Generalized Integrator [Volume 3, Issue 1, 2024, Pages 1-8]
B
Back contacts geometry engineeringImprovement of IBC-SHJ Solar Cell Efficiency Based on Back Contacts Geometry Engineering [Volume 3, Issue 1, 2024, Pages 83-89]
C
ConsensusConsensus-Based Algorithm for Distributed Continuous-Time Convex Optimization Over Undirected and Directed Networks [Volume 3, Issue 1, 2024, Pages 74-82]
Contingency analysisReliability Evaluation of Power Systems Including Pumped-Storage Generation Units [Volume 3, Issue 1, 2024, Pages 110-119]
DampingOptimization of PSS and UPFC Controllers to Enhance Stability by Using a Combination of Fuzzy Algorithm and Shuffled Frog Leaping Algorithm [Volume 3, Issue 2, 2024, Pages 168-176]
DC-DC current convertersConventional DC-DC Converters Through Duality Approach for Current-Based Applications [Volume 3, Issue 1, 2024, Pages 64-73]
DC deviationImproving the Performance of a VSG in the Distorted Grid Using Third-Order Generalized Integrator [Volume 3, Issue 1, 2024, Pages 1-8]
DC microgridEfficient Responding to Demand and Robust Voltage Control of an Islanded DC Microgrid Under Variations in Load and Supply [Volume 3, Issue 1, 2024, Pages 51-63]
Demand responseDemand Response Design for Healthy Operation of Transformers in Heavy-Load and High-Temperature Conditions [Volume 3, Issue 1, 2024, Pages 90-98]
Demand responseAssessing Power System Adequacy and Generation Expansion Planning in the Presence of Wind Power Plants Considering Uncertainties in the DIgSILENT Software Environment [Volume 3, Issue 1, 2024, Pages 99-109]
DFIGWide Area Robust Controller Design for SSSC to Improve the Oscillations Caused by the Time Delay of Remote Signals [Volume 3, Issue 2, 2024, Pages 120-135]
Diode-based Voltage-Limiter (DVL)A New Topological Method for Output Voltage Clamping of Immittance-based Constant Current Load Resonant Converters [Volume 3, Issue 1, 2024, Pages 33-39]
Distributed convex optimizationConsensus-Based Algorithm for Distributed Continuous-Time Convex Optimization Over Undirected and Directed Networks [Volume 3, Issue 1, 2024, Pages 74-82]
Distributed generation sourcesVoltage Regulation in Low Voltage Distribution Networks Using Reactive Power Capability of Photovoltaic Inverters and PID Consensus Algorithm [Volume 3, Issue 2, 2024, Pages 159-167]
Distributed resourcesImproving the Performance of a VSG in the Distorted Grid Using Third-Order Generalized Integrator [Volume 3, Issue 1, 2024, Pages 1-8]
DSTATCOMImproving Power Quality Using a Fuzzy Inference System-Based Variable Forgetting Factor Recursive Least Error Square Control Scheme of DSTATCOM [Volume 3, Issue 2, 2024, Pages 185-199]
Duality approachConventional DC-DC Converters Through Duality Approach for Current-Based Applications [Volume 3, Issue 1, 2024, Pages 64-73]
Dust stormInvestigating the Flashover Probability of Transmission Network Insulators During Dust Storms [Volume 3, Issue 2, 2024, Pages 207-221]
E
Economic Emission Dispatch (EED)Solving Combined Economic Emission Dispatch Problem Using the Rain Optimization Algorithm [Volume 3, Issue 1, 2024, Pages 19-32]
Electric vehicleEconomic Analysis of Photovoltaic Systems During Peak Load of the Electric Power Distribution System in the Presence of Electric Vehicles [Volume 3, Issue 2, 2024, Pages 177-184]
F
Finite element methodImproving the Performance Characteristics of Conventional Linear Switched Reluctance Motor by Eliminating Translator Yoke and Embedding Permanent Magnets in Stator Yoke [Volume 3, Issue 2, 2024, Pages 222-231]
Fragility curveInvestigating the Flashover Probability of Transmission Network Insulators During Dust Storms [Volume 3, Issue 2, 2024, Pages 207-221]
Fuzzy Logic Variable Forgetting FactorImproving Power Quality Using a Fuzzy Inference System-Based Variable Forgetting Factor Recursive Least Error Square Control Scheme of DSTATCOM [Volume 3, Issue 2, 2024, Pages 185-199]
G
Grid stabilityImproving the Performance of a VSG in the Distorted Grid Using Third-Order Generalized Integrator [Volume 3, Issue 1, 2024, Pages 1-8]
H
Hot spot temperatureDemand Response Design for Healthy Operation of Transformers in Heavy-Load and High-Temperature Conditions [Volume 3, Issue 1, 2024, Pages 90-98]
HumidityInvestigating the Flashover Probability of Transmission Network Insulators During Dust Storms [Volume 3, Issue 2, 2024, Pages 207-221]
I
IBC-SHJ solar cellImprovement of IBC-SHJ Solar Cell Efficiency Based on Back Contacts Geometry Engineering [Volume 3, Issue 1, 2024, Pages 83-89]
Immittance Passive Resonant Tank (IPRT)A New Topological Method for Output Voltage Clamping of Immittance-based Constant Current Load Resonant Converters [Volume 3, Issue 1, 2024, Pages 33-39]
Injection InsulinInvestigating Robust Tracking of Type 1 Diabetes Control Using Model-Free Controllers [Volume 3, Issue 2, 2024, Pages 232-239]
InsulatorInvestigating the Flashover Probability of Transmission Network Insulators During Dust Storms [Volume 3, Issue 2, 2024, Pages 207-221]
Intelligent reflecting surface (IRS)IRS-Assisted Visible Light Communication for Improved Monitoring of Patient Vital Signals in Hospital Environment [Volume 3, Issue 2, 2024, Pages 240-249]
L
Linear matrix inequalityWide Area Robust Controller Design for SSSC to Improve the Oscillations Caused by the Time Delay of Remote Signals [Volume 3, Issue 2, 2024, Pages 120-135]
Linear switched reluctance motorImproving the Performance Characteristics of Conventional Linear Switched Reluctance Motor by Eliminating Translator Yoke and Embedding Permanent Magnets in Stator Yoke [Volume 3, Issue 2, 2024, Pages 222-231]
Lithium-ion batteriesComparative Analysis of Lithium-ion Battery for Long and Short Pulse Discharge Experiments in State-of-Charge Estimation with Extended Kalman Filter [Volume 3, Issue 2, 2024, Pages 200-206]
Load Duration CurveReliability Evaluation of Power Systems Including Pumped-Storage Generation Units [Volume 3, Issue 1, 2024, Pages 110-119]
Load Resonant Converter (LRC)A New Topological Method for Output Voltage Clamping of Immittance-based Constant Current Load Resonant Converters [Volume 3, Issue 1, 2024, Pages 33-39]
M
MetaheuristicOptimization of PSS and UPFC Controllers to Enhance Stability by Using a Combination of Fuzzy Algorithm and Shuffled Frog Leaping Algorithm [Volume 3, Issue 2, 2024, Pages 168-176]
MicrogridVoltage and Frequency Control Considering Disturbance in Input Power of DG [Volume 3, Issue 1, 2024, Pages 9-18]
Model-FreeInvestigating Robust Tracking of Type 1 Diabetes Control Using Model-Free Controllers [Volume 3, Issue 2, 2024, Pages 232-239]
Multi-agent systemConsensus-Based Algorithm for Distributed Continuous-Time Convex Optimization Over Undirected and Directed Networks [Volume 3, Issue 1, 2024, Pages 74-82]
O
OptimizationOptimization of PSS and UPFC Controllers to Enhance Stability by Using a Combination of Fuzzy Algorithm and Shuffled Frog Leaping Algorithm [Volume 3, Issue 2, 2024, Pages 168-176]
P
PID ControllerInvestigating Robust Tracking of Type 1 Diabetes Control Using Model-Free Controllers [Volume 3, Issue 2, 2024, Pages 232-239]
PID voltage controlVoltage Regulation in Low Voltage Distribution Networks Using Reactive Power Capability of Photovoltaic Inverters and PID Consensus Algorithm [Volume 3, Issue 2, 2024, Pages 159-167]
Piezoelectric energy harvestingAnalysis of the Potential of Different Air Conditioner Brands for Piezoelectric Energy Harvesting [Volume 3, Issue 1, 2024, Pages 40-50]
Power QualityImproving Power Quality Using a Fuzzy Inference System-Based Variable Forgetting Factor Recursive Least Error Square Control Scheme of DSTATCOM [Volume 3, Issue 2, 2024, Pages 185-199]
Power systemWide Area Robust Controller Design for SSSC to Improve the Oscillations Caused by the Time Delay of Remote Signals [Volume 3, Issue 2, 2024, Pages 120-135]
Pumped-Storage Power PlantReliability Evaluation of Power Systems Including Pumped-Storage Generation Units [Volume 3, Issue 1, 2024, Pages 110-119]
Q
Q-LearningInvestigating Robust Tracking of Type 1 Diabetes Control Using Model-Free Controllers [Volume 3, Issue 2, 2024, Pages 232-239]
R
Rankine cycleReliability Modelling of Central Receiver Power Plants [Volume 3, Issue 2, 2024, Pages 250-260]
Recursive Least Error SquareImproving Power Quality Using a Fuzzy Inference System-Based Variable Forgetting Factor Recursive Least Error Square Control Scheme of DSTATCOM [Volume 3, Issue 2, 2024, Pages 185-199]
ReliabilityAssessing Power System Adequacy and Generation Expansion Planning in the Presence of Wind Power Plants Considering Uncertainties in the DIgSILENT Software Environment [Volume 3, Issue 1, 2024, Pages 99-109]
ReliabilityReliability Evaluation of Power Systems Including Pumped-Storage Generation Units [Volume 3, Issue 1, 2024, Pages 110-119]
ReliabilityReliability Modelling of Central Receiver Power Plants [Volume 3, Issue 2, 2024, Pages 250-260]
Renewable energy sourcesEfficient Responding to Demand and Robust Voltage Control of an Islanded DC Microgrid Under Variations in Load and Supply [Volume 3, Issue 1, 2024, Pages 51-63]
Response fatigue indexDemand Response Design for Healthy Operation of Transformers in Heavy-Load and High-Temperature Conditions [Volume 3, Issue 1, 2024, Pages 90-98]
S
Solar energyEconomic Analysis of Photovoltaic Systems During Peak Load of the Electric Power Distribution System in the Presence of Electric Vehicles [Volume 3, Issue 2, 2024, Pages 177-184]
Solar radiationReliability Modelling of Central Receiver Power Plants [Volume 3, Issue 2, 2024, Pages 250-260]
SSSCWide Area Robust Controller Design for SSSC to Improve the Oscillations Caused by the Time Delay of Remote Signals [Volume 3, Issue 2, 2024, Pages 120-135]
StabilityWide Area Robust Controller Design for SSSC to Improve the Oscillations Caused by the Time Delay of Remote Signals [Volume 3, Issue 2, 2024, Pages 120-135]
System adequacy assessmentAssessing Power System Adequacy and Generation Expansion Planning in the Presence of Wind Power Plants Considering Uncertainties in the DIgSILENT Software Environment [Volume 3, Issue 1, 2024, Pages 99-109]
T
Tracking Blood GlucoseInvestigating Robust Tracking of Type 1 Diabetes Control Using Model-Free Controllers [Volume 3, Issue 2, 2024, Pages 232-239]
Transformer thermal modelDemand Response Design for Healthy Operation of Transformers in Heavy-Load and High-Temperature Conditions [Volume 3, Issue 1, 2024, Pages 90-98]
Transmission networkInvestigating the Flashover Probability of Transmission Network Insulators During Dust Storms [Volume 3, Issue 2, 2024, Pages 207-221]
Transmission SystemReliability Evaluation of Power Systems Including Pumped-Storage Generation Units [Volume 3, Issue 1, 2024, Pages 110-119]
U
UncertaintyAssessing Power System Adequacy and Generation Expansion Planning in the Presence of Wind Power Plants Considering Uncertainties in the DIgSILENT Software Environment [Volume 3, Issue 1, 2024, Pages 99-109]
V
Virtual synchronous generatorImproving the Performance of a VSG in the Distorted Grid Using Third-Order Generalized Integrator [Volume 3, Issue 1, 2024, Pages 1-8]
W
WAMSWide Area Robust Controller Design for SSSC to Improve the Oscillations Caused by the Time Delay of Remote Signals [Volume 3, Issue 2, 2024, Pages 120-135]